<annex-type> Type of Annex
This element acts as a flag whose content can be both interrogated and displayed.
It answers the question, “Is this Annex (<app>) normative or informative (non-normative)?”. The element content is expected to be
“(normative)” or “(informative)”.
Usage/Remarks
The element content is expected to be “(normative)”
or “(informative)”; however, other values
may be needed in contexts this work does not anticipate.
Strictly speaking, this element is redundant with the appendix (<app>) element’s @content-type attribute, whose expected values are
“norm-annex” and “inform-annex”. The description of the annex type in this element is intended for display to the
end user, so the element should contain the text that will print/display in the formatted
standard.
Models and Context
May be contained in
Description
Text, numbers, or special characters
Content Model
<!ELEMENT annex-type (#PCDATA) >
Tagged Samples
For informative annex
...
<back>
<app-group>
<app content-type="inform-annex" id="annA">
<label>Annex A</label>
<annex-type>(informative)</annex-type>
<title>Global trends supporting accessibility</title>
...
<sec id="A1">
<label>A.1</label>
<title>Trends in global demographics and market diversity</title>
<p>According to the <italic>World Report on Disability</italic>
(published by the World Health Organization and the World Bank
in June 2011,<sup><xref ref-type="bibr" rid="bibr40">[40]</xref></sup>
approximately 15 % of the world population (over one billion
people) has ...</p>
</sec>
...
</app>
</app-group>
<ref-list>...</ref-list>
</back>
...
For normative annex
...
<back>
...
<app-group>
<app content-type="norm-annex" id="annA">
<label>Annex A</label>
<annex-type>(normative)</annex-type>
<title>General operational requirements</title>
<sec id="annA.1">
<label>A.1</label>
<title>Installation, operation and maintenance
— general</title>
<p>The manufacturer shall specify in documentation
provided for or available to the installer, user and
maintainer of the equipment the conditions for ...</p>
...
</sec>
...
</app>
...
</app-group>
</back>
...
Multiple annexes
... <back> ... <app-group> <app content-type="norm-annex" id="annA"> <label>Annex A</label> <annex-type>(normative)</annex-type> <title>Specification for welded jointers</title> <sec id="annA.1"> <label>A.1</label> <title>Method</title> <sec id="annA.1.1"> <label>A.1.1</label> <p>Welding of any type that uses deposited filler metal and is ...</p> </sec> ... </sec> ... </app> <app content-type="norm-annex" id="annB"> <label>Annex B</label> <annex-type>(normative)</annex-type> <title>Manufacturing procedure qualification for PSL 2 pipe</title> <sec id="annB.1"> <label>B.1</label> <title>Introduction</title> <sec id="annB.1.1"> <label>B.1.1</label> <p>This annex specifies additional provisions that apply if manufacturing procedure qualification is ...</p> </sec> ... </sec> ... </app> ... </app-group> </back> ...
Annex and multiple appendixes
<standard xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:tbx="urn:iso:std:iso:30042:ed-1" dtd-version="1.0" xml:lang="en"> <front>...</front> <body>...</body> <back> <app-group content-type="annex"> <title>ANNEX</title> <app> <label>A1</label> <annex-type>(Mandatory Information)</annex-type> <title>ANALYZER PRECISION AND BIAS</title> <sec> <label>A1.1</label> <title>Bias at Zero Concentration</title> <p>Most analyzers ...</p> </sec> </app> </app-group> <app-group content-type="appendix"> <title>APPENDIXES</title> <app> <label>X1</label> <annex-type>(Nonmandatory Information)</annex-type> <title>TRACER GASES USED TO DETERMINE AIR CHANGE</title> <sec> <label>X1.1</label> <p>Table X1.1 and Table X1.2 list ...</p> </sec> </app> <app> <label>X2</label> <annex-type>(Nonmandatory Information)</annex-type> <title>CALIBRATION OF CERTAIN GAS ANALYZERS</title> <sec> <label>X2.1</label> <title>Applicability</title> <p>Certain gas analyzers, including ...</p> </sec> </app> <app> <label>X3</label> <annex-type>(Nonmandatory Information)</annex-type> <title>CONFIDENCE INTERVALS</title> <sec> <label>X3.1</label> <title>Concentration Decay Method</title> <sec> <label>X3.1.1</label> <title>Test for Constant A</title> <p>The following ...</p> </sec> </sec> </app> </app-group> </back> </standard>